Master’s Thesis: Phase-Contrast X-ray Imaging of Advanced Semiconductor Packages
Do you want to help reveal what conventional X-ray imaging cannot see? Excillum develops the world’s brightest laboratory X-ray sources, and we are looking for a master’s student in physics, electrical engineering, applied mathematics or a similar field who is excited about X-ray phase-contrast imaging, advanced semiconductor packaging and experimentation.
About Excillum
At Excillum, we push the boundaries of X-ray technology to enable breakthroughs in manufacturing, medicine and science. Our advanced X-ray sources enhance the manufacturing of semiconductors, batteries, electronics and aerospace components, as well as enable new biomedical and material sciences. They make our customers’ X-ray systems faster and better with lower cost of operation.
Founded in 2007 by researchers from KTH, Excillum has grown into a global leader in advanced microfocus and nanofocus X-ray sources. Today, our products are used by leading industrial companies, instrument manufacturers and research institutions around the world.
About the project
X-ray phase-contrast imaging can improve the visibility of low-density features that produce weak absorption contrast. Used in fields such as medical soft-tissue imaging and materials science, it exploits phase shifts caused by the refractive index of different materials in the sample, complementing conventional absorption-based contrast.
Advanced packaging is a key technique improving the performance of modern electronic components. Next-generation high-end chips incorporate co-packaged optics, silicon photonics and waveguides for data transmission, as well as glass substrates. Thermal-interface materials are another important type of low-density feature in advanced packages. Non-destructive inspection of these structures remains challenging, and high-resolution phase-contrast imaging may offer a solution. However, metal layers and interconnects can strongly attenuate the low-energy X-rays required for phase contrast, creating a trade-off between sensitivity to low-density features and penetration through the package.
This thesis will evaluate the feasibility of using 3D X-ray phase-contrast imaging with nano-CT and/or laminography to inspect low-density structures in advanced electronic packages. Simulations will first assess feasibility and optimise our in-house imaging system. The most promising conditions will then be tested in a proof-of-concept experiment, with the possibility to perform further measurements if time permits.
What you will do
Review the benefits and limitations of different X-ray phase-contrast imaging methods
Simulate representative phase-contrast imaging use cases for electronic packages using our in-house simulation software
Optimise key imaging parameters, including the X-ray spectrum, detector and scan geometry
Validate the selected conditions experimentally
If time permits, compare different target materials
If time permits, evaluate different detectors
What you will learn
X-ray imaging and CT
Phase contrast imaging
Image simulation
Practical work with advanced laboratory instruments
Who you are
You are a master’s student in physics, electrical engineering, applied mathematics or a similar field, with a genuine interest in X-ray physics and simulation. You enjoy turning physics into models, and models into tools that others can use. To succeed in this project, we believe you have:
Programming skills in Python
Basic knowledge of X-ray physics and imaging
Good communication skills in English
It is a strong merit if you have knowledge of X-ray imaging, CT, phase contrast or image simulation.
Practical information
Level: Master’s thesis, 30 credits
Start: Early 2027
Location: Excillum, Jan Stenbecks torg 17, Kista – at least 50% on-site
Working language: English
Supervisors: Jenny Romell & Till Dreier
Project owner: Till Dreier
Compensation: SEK 15,000 halfway through the project and an additional SEK 15,000 upon successful completion. Excillum also covers project-related expenses such as travel and materials.
Apply
To apply, please submit your CV, a cover letter and a copy of your academic transcripts.
We look forward to your application! If you have any questions regarding the thesis, do not hesitate to contact Hugo Högberg West at hugo.hogberg@excillum.com.
- Department
- Thesis Projects
- Location
- Kista
- Remote status
- Hybrid
Kista
On top
-
Autonomy
We trust the employees in planning their work and finding the way to the goal, we know this is highly appreciated by our employees.
-
Grow your skill-set
Being a small company with a global reach and a multi-disciplinary technology we really enable you to grow your skill-set.
-
Energized by our mission
Our mission is to enable new science, improve medicine and enhance manufacturing by continuous development of state-of-the-art X-ray sources.
This is a true purpose. With this on top of mind you will get things done.
-
Extras
To help you go beyond we offer parental leave compensation, sick leave compensation, health care insurance, pension, team outings, flexible working hours, possibility to work remotely to mention a few extras. This is of course on top of a competitive compensation.
Life at Excillum
Excillum people are guided by a casual, open-office environment that enables interaction and collaboration between people and teams. The experimental tradition is strong where you will be encouraged to test and move quickly with new ideas. Working close to the mission, each employee really has an impact on our success – and every success is celebrated by the whole team.
About Excillum
Excillum is a leading company in the field of high-end microfocus and nanofocus X-ray sources. Excillum was founded in 2007 by researchers from the Royal Institute of Technology (KTH) Stockholm, Sweden. The first product was market released in 2010, the MetalJet. Our mission is to enable new science, improve medicine and enhance manufacturing by continuos development of state-of-the-art X-ray sources.